# FTTH splits, capacity and optics

Compare physical splitter choices while keeping subscriber counts and service demand explicit. All numeric presets are invented teaching assumptions, not equipment specifications.

## Try these decisions

1. Start with four PONs, 32 subscribers on each, and a 1:32 split. Save the design for comparison.
2. Change to 1:64 without adding subscribers. Compare output occupancy and optical loss. Traffic does not change simply because the split changes.
3. Try 1:4 x 1:8. The ratios multiply to 32 outputs. Along one ONT path, light passes the first stage and one second-stage splitter. Their insertion losses add in dB.
4. Try the worked 1:16 redesign. Keeping 128 subscribers requires eight populated PON ports instead of four. Compare per-PON demand and total uplink demand.
5. Double the traffic, double the fiber, and remove an uplink in separate experiments. Identify which budget each change affects.

## Read the calculations

- Per-PON demand = connected subscribers per PON x assumed busy-hour demand per subscriber x traffic growth multiplier.
- Aggregate demand = identical PON port count x per-PON demand.
- Normal uplink capacity = equal active uplink count x usable capacity per uplink. The single-failure case removes one uplink.
- Component path loss = fiber length x attenuation + splitter insertion losses + connector-pair losses + splice losses + other path loss.
- Upper optical headroom = maximum permitted path loss - component path loss - design reserve.
- The minimum-loss check uses physical component loss. A design reserve does not add physical attenuation.
- Use specified insertion loss once. Do not add ideal splitting loss to an insertion-loss value that already includes it.

The declared baseline gives 1,920 Mbps downstream and 480 Mbps upstream per PON, 23.3 dB component path loss, and 1.7 dB upper headroom after reserve. These results apply only to the lab's unchanged baseline.

## Discuss the split choice

| Choice | Possible benefit | Questions to take to a design review |
| --- | --- | --- |
| Centralized, single stage | Concentrates patching and simplifies reassignment | Distribution fiber count, cabinet space, access, and feeder routes |
| Cascaded, two stages | Shares distribution fibers toward smaller groups | Spare outputs by branch, field locations, joints, and fault isolation |
| Lower total split | Reduces ideal split loss and potential sharers per PON | Extra PON ports, optics, licenses, fibers, and migration work |

Take rate and split ratio describe different things. Sixteen subscribers among 32 homes passed is 50% take rate. Those ONTs still experience the insertion loss of the selected splitter.

## Limits and evidence

The model uses identical PONs and equal, full-duplex, concurrently usable uplinks. It does not model dynamic bandwidth allocation, bursts, queues, per-flow hashing, shared conduits, interoperability, or single-flow throughput. The optical calculation covers one path, wavelength, and direction. Check every relevant direction and path against actual component and equipment specifications. Unbalanced taps require a different model.

Use the browser lab to change inputs, compare designs, and download or restore assumptions. Inputs stay in the browser; the lab does not contact equipment.

## Continue

- [Open the interactive lab](https://oaktowntech.com/wp-content/uploads/oaktown-field-notes-v76/ftth-planning.html)
- [Browse all labs](https://oaktowntech.com/labs/)
- [Read Field Notes](https://oaktowntech.com/field-notes/)